What's the Difference Between Single and Dual Beam Spectrophotometers?

New Products Spectrophotometers

Sper Scientific UV Spectrophotometers

Understanding the differences between single beam and dual beam Spectrophotometers is crucial for choosing the right instrument for your laboratory requirements. In this article we'll take a dive into some of the key differences between these two types of critical instruments.

How does a Single Beam Spectrophotometer work?

A single beam spectrophotometer measures light intensity by passing a single light beam through a sample. However, to obtain accurate readings, a baseline (reference) reading must be taken separately using a blank solution. This manual process involves taking a blank reading, then replacing it with the sample for measurement.

What about Reference Handling?

Single beam spectrophotometers have manual reference handling, which means that the user needs to take the blank reading and then swap it with the sample for measurement. This method can be prone to errors and inconsistencies.

Stability Comparison

Due to the manual reference handling and lack of continuous comparison between the sample and reference, single beam spectrophotometers are more susceptible to drift over time. This can impact the accuracy and reliability of the measurements taken.

Cost Considerations

Single beam spectrophotometers are generally somewhat less expensive than dual beam models. This is due to a simpler design with fewer optical components, making them a budget-friendly option for basic lab work, teaching labs and applications where simplicity is key.

What sets Dual Beam Spectrophotometers apart?

Dual beam spectrophotometers split the light into two beams — one for the sample and one for the reference. This design allows for simultaneous measurement of the sample and reference, providing more accurate and stable results compared to single beam spectrophotometers.

When choosing between single beam and dual beam spectrophotometers, you'll want to consider factors such as reference handling, stability, cost and intended use case. Each type has its advantages and limitations, so here's a rundown:

Key Differences

Feature Single Beam Dual Beam
Measurement Mode Sequential (blank then sample) Simultaneous (sample & reference)
Light Path One path Two paths (split beam)
Stability Lower (sensitive to drift) Higher (auto compensation)
Complexity & Cost Simpler, cheaper More complex, more expensive
Ideal For Teaching, basic testing Research, QA/QC, high-precision

Single Beam Spectrophotometers

  • Operation: Measures light intensity by passing a single light beam through a sample. A baseline (reference) reading must be taken separately using a blank.

  • Reference Handling: Manual - you take a blank reading, then replace it with the sample.

  • Stability: More susceptible to drift over time since it doesn't continuously compare sample and reference.

  • Cost: Lower - simpler design with fewer optical components.

  • Use Case: Good for basic lab work, teaching labs, and applications where budget or simplicity is key.

Recommended models:

SPSV-5100/SPSUV-5100 | UV/Visible Light Spectrophotometer

SPSV-5100/SPSUV-5100 Visible Light Spectrophotometer


 

SPSUV-5800 SPSV-5800 Visible lIght Spectrophotometer

SPSV-5800/SPSUV-5800 Visible Light Spectrophotometer


 

SPSUV 6100 Series Single Beam Spectrophotometer

SPSUV-6100 Series UV Visible Spectrophotometer for DNA/RNA/Protein Analysis

 



Dual Beam Spectrophotometers

  • Operation: Splits the light into two beams — one goes through the sample, the other through a reference (blank) simultaneously.

  • Reference Handling: Continuous — automatically compensates for fluctuations in lamp intensity, detector response, and other variables.

  • Stability: More stable and accurate, especially over long runs or with varying light source output.

  • Cost: Higher — more complex optical setup.

  • Use Case: Preferred for research labs, quality control, and any application requiring high precision or frequent measurement over time.

Recommended models:

SPSUV-9000AS double beam spectrophotometer

SPSUV-9000 Series Double Beam Spectrophotometer






Summary

Single beam and dual beam spectrophotometers differ primarily in how they handle light measurement and reference correction. A single beam spectrophotometer measures light intensity by passing it through a sample after a separate blank reference has been measured. This simpler design makes single beam systems more affordable and compact but also more prone to drift and less stable over time, as they do not continuously correct for fluctuations in light source intensity or detector response.

In contrast, a dual beam spectrophotometer splits the light into two paths: one passes through the sample and the other through a reference blank. This simultaneous comparison enables real-time correction of background noise and instrument variability, resulting in higher accuracy and stability. While dual beam systems are more complex and expensive, they are better suited for high-precision applications, extended measurements, and rigorous quality control environments.

 