{"product_id":"uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator","title":"UTS3015T+ 1.5 GHz Spectrum Analyzer with Tracking Generator","description":"\u003ch1\u003eThe UTS3015T+ and UTS3032T+ bring 1.5 GHz and 3.2 GHz spectrum analysis, a built-in tracking generator, and reflection measurement into a single bench instrument under two thousand dollars.\u003c\/h1\u003e\n\u003cp\u003eFor a small hardware team or a contract test bench, that means one box covers signal search, scalar network checks, and pre-compliance screening without three separate purchases.\u003c\/p\u003e\n\u003cp\u003eBoth models hold a typical displayed average noise level to −161 dBm (preamp on, a shared series figure), phase noise below −98 dBc\/Hz at 10 kHz offset, and full-amplitude accuracy under 0.7 dB — numbers that hold up under real measurement conditions, not peak-only figures. A 10.1-inch 1280×800 capacitive touch screen and full SCPI control over USB and LAN make the instrument scriptable from day one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTracking generator is built in\u003c\/strong\u003e on every T+ model — it is the defining difference of the T+ line and is standard, not an added option. Analog demodulation, the advanced measurement kit, and EMI pre-compliance remain field-installable options when a project needs them.\u003c\/p\u003e\n\u003ch2\u003eChoosing Your Model: UTS3000T+ Performance-Series\u003c\/h2\u003e\n\u003cp\u003eThe UTS3000T+ name spans two materially different instrument classes. The four models below do not share the same sweep engine, trace count or demodulation capability — the differences go well beyond frequency reach. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout: fixed; width: 100%; height: 235.208px;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 28%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3015T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3015T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3032t-3-2-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3032T+ Spectrum Analyzer\"\u003eUTS3032T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3036t-3-6-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3036T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3036T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3084t-8-4-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3084T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3084T+\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eSweep (scan) points\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eTraces\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAnalog demodulation (option)\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eTracking generator range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e10 MHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eResolution bandwidth\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eBuilt-in tracking generator\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWithin the UTS3015T+\/UTS3032T+ class, choose by frequency reach (1.5 GHz vs 3.2 GHz). Within the UTS3036T+\/UTS3084T+ class, choose 3.6 GHz or 8.4 GHz reach. Across classes the UTS3036T+\/UTS3084T+ models add a 40,001-point sweep (4× the depth), six traces instead of four, and PM demodulation in addition to AM\/FM — confirm which class a model belongs to before assuming a shared specification.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 3.6 GHz or 8.4 GHz\u003c\/strong\u003e — 9 kHz lower edge to 3.6 GHz (UTS3036T+) or 8.4 GHz (UTS3084T+), reaching higher harmonics and wideband signals the sub-3 GHz class cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,001 sweep points, six traces\u003c\/strong\u003e — Four times the sweep depth of the entry pair, with six independent traces for simultaneous live, reference and limit comparison.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar network response on filters, amplifiers and cables; TG output to 6 GHz on the UTS3084T+.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−165 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level (10–200 MHz band) for weak-signal and low-level emissions work — a shared series figure, the same for both models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz RBW, \u0026lt; 4.8:1 shape factor\u003c\/strong\u003e — Fine resolution and selectivity for closely spaced unequal-amplitude signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise to −110 dBc\/Hz at 1 MHz\u003c\/strong\u003e — Close-in phase-noise figures suited to oscillator and synthesizer characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) for automated frequency\/level\/span sweeps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-compliance and analog demodulation options\u003c\/strong\u003e — CISPR-aware screening with quasi-peak\/EMI-average detectors; AM\/FM\/PM demodulation with SINAD and THD readout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UTS3000T+ Performance-Series Details\u003c\/h2\u003e\n\u003ch3\u003eFrequency Reach to 8.4 GHz\u003c\/h3\u003e\n\u003cp\u003eThe UTS3036T+ sweeps 9 kHz to 3.6 GHz; the UTS3084T+ to 8.4 GHz. The higher ceiling captures the third and higher harmonics of sub-3 GHz carriers and wideband spurious content that a 3 GHz-class analyzer cannot reach.\u003c\/p\u003e\n\u003ch3\u003e40,001-Point Sweep\u003c\/h3\u003e\n\u003cp\u003eEach trace carries 40,001 points — four times the entry pair — so a wide span still resolves narrow signals without sacrificing the span to keep frequency resolution. This is the practical difference when searching a multi-GHz window for a single spur.\u003c\/p\u003e\n\u003ch3\u003eSix Traces and Detector Modes\u003c\/h3\u003e\n\u003cp\u003eSix independent traces with Sample, Peak, Negative, Normal and Average detectors allow live, max-hold, reference and limit traces on screen at once — useful when comparing a measured spectrum against a stored mask.\u003c\/p\u003e\n\u003ch3\u003eSensitivity and Phase Noise\u003c\/h3\u003e\n\u003cp\u003eTypical displayed average noise level reaches −165 dBm with the preamp on (10–200 MHz band) — a shared series figure for both models. Phase noise is −98 dBc\/Hz typical at 10 kHz and reaches −110 dBc\/Hz at 1 MHz offset on the UTS3084T+, relevant when measuring a clean source close to the carrier.\u003c\/p\u003e\n\u003ch3\u003eReflection Measurement\u003c\/h3\u003e\n\u003cp\u003eWith the optional VSWR bridge and the built-in tracking source, the analyzer measures S11 return loss, reflection coefficient and VSWR after an Open calibration — antenna and cable verification on the same instrument.\u003c\/p\u003e\n\u003ch3\u003eEMI Pre-Compliance Screening (Option)\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit the analyzer operates as a CISPR-aware screening receiver: −6 dB resolution bandwidths of 200 Hz, 9 kHz, 120 kHz and 1 MHz; Peak, Negative-Peak, Quasi-Peak, EMI-Average and Average detectors; up to three concurrent meter traces; and editable limit-line sets for FCC, EN, MIL-STD-461, DO-160, VCCI and custom standards. A Scan \/ Search \/ Measure sequence with output report supports near-field-probe emissions screening before committing to chamber time.\u003c\/p\u003e\n\u003ch3\u003eAnalog Demodulation Analysis (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMA kit adds AM, FM and PM demodulation. Modulation rate covers 20 Hz to 100 kHz; AM depth 5–95%; FM offset 1 kHz to 400 kHz; PM phase deviation 0.2 to 6.28 rad. The result window reports modulation depth, carrier power, modulation frequency, SINAD and THD — enough to verify a transmitter's modulation quality from the same bench.\u003c\/p\u003e\n\u003ch3\u003eAdvanced One-Key Measurements (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMK kit adds channel power, power spectral density, adjacent-channel power, occupied bandwidth, transmit frequency error, zero-span (time-domain) power, carrier-to-noise ratio, third-order intercept and harmonic measurement to the 10th order, plus a spectrogram monitor — the transmitter-test set used in design verification.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eRF and Wireless Design Engineering\u003c\/h3\u003e\n\u003cp\u003eAbove 3 GHz the work is harmonic and spurious search, wideband signal characterization, and source verification. The 8.4 GHz reach of the UTS3084T+ captures the higher harmonics of a sub-3 GHz design; the 40,001-point sweep keeps narrow signals resolved across a multi-GHz span; and the close-in phase-noise figures support oscillator and synthesizer characterization. Full SCPI over LAN runs the level- and frequency-stepped sweeps a characterization report needs, unattended.\u003c\/p\u003e\n\u003ch3\u003ePre-Compliance and Multi-Function Test Benches\u003c\/h3\u003e\n\u003cp\u003eFor a lab that needs more than one instrument's worth of capability per bench, this pair consolidates spectrum analysis, scalar network response via the built-in tracking generator, reflection measurement, AM\/FM\/PM demodulation and CISPR-aware EMI screening into one instrument. Early emissions screening with a near-field probe set catches problems before chamber time; the advanced-measurement kit covers the transmitter test set for design verification — all option installs, no recurring license.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 1.5 GHz or 3.2 GHz\u003c\/strong\u003e — 9 kHz lower edge to a 1.5 GHz (UTS3015T+) or 3.2 GHz (UTS3032T+) upper edge, covering HF through the common sub-3 GHz ISM, IoT and wireless bands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar frequency-response and insertion-loss measurement on filters, amplifiers and cables without a separate source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge — antenna and cable checks on the same bench.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−161 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level for weak-signal work near the noise floor — a shared series figure, identical across both models at their top frequencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz resolution bandwidth\u003c\/strong\u003e — 1-3-10 steps with \u0026lt; 4.8:1 shape factor to separate closely spaced signals of unequal amplitude.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,001 sweep points, four traces\u003c\/strong\u003e — Per-trace resolution across the full span with four independent traces and five detector modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch multi-touch interface\u003c\/strong\u003e — 1280×800 capacitive screen with drag, pinch and zoom on the trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) with SCPI for scripted, repeatable test sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption-extensible\u003c\/strong\u003e — Add analog demodulation, the advanced measurement kit, or EMI pre-compliance as the work requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 1.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz, 100 Hz to 1.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelectivity (60\/3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4.8:1 (60 dB \/ 3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points \/ trace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSample, Peak, Negative, Normal, Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (typical, preamp on)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etypical displayed average noise level to -161 dBm (preamp on, 500 kHz-200 MHz band; identical at each model's top frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; -98 dBc\/Hz @ 10 kHz offset (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 dB full-amplitude accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 dBm to +30 dBm, 1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreamplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 dB (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 51 dB, 1 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax safe input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V DC; \u0026lt;= +33 dBm (3 min, input attenuation \u0026gt; 20 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking generator range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz to 1.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTG output level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 dBm to 0 dBm, 0.5 dB resolution, +\/-3 dB flatness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReflection measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVSWR, return loss, reflection coefficient (S11); requires VSWR bridge + tracking source; excitation -20 to 0 dBm, Open calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog demod (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM — UTS3015T+ 2 MHz to 1.5 GHz, UTS3032T+ 2 MHz to 3.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced measurement kit (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel power, power spectral density, ACP, occupied bandwidth, transmit frequency error, zero-span (T-power), CNR, TOI, harmonics (to 10th), spectrum monitor \/ spectrogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMI pre-compliance (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR RBWs 200 Hz\/9 kHz\/120 kHz\/1 MHz; Peak\/Neg-Peak\/Quasi-Peak\/EMI-Avg\/Avg detectors; editable limit lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280x800 capacitive multi-touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (USB-A), USB-Device (USB-B), LAN (VXI11) 10\/100\/1000Base RJ-45, HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull SCPI remote control over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e378 mm x 218 mm x 120 mm (W x H x L); 4.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 C to +40 C operating; -20 C to +70 C non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories and Family Options\u003c\/h3\u003e\n\u003cp\u003eThe tracking generator is built in on every UTS3036T+ \/ UTS3084T+ model. Field-installable options: UTS3000-AMA Analog Demodulation, UTS3000-AMK Advanced Measurement Kit, UTS3000-EMI EMI Pre-Compliance. The tracking generator is standard — it is not an added option on the T+ line.\u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eDoes the tracking generator cost extra on the T+?\u003c\/h3\u003e\n\u003cp\u003eNo. The tracking generator is built in and standard on every UTS3000T+ model, including the UTS3015T+ and UTS3032T+. It is the defining feature of the T+ line.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the UTS3015T+ and the UTS3032T+?\u003c\/h3\u003e\n\u003cp\u003eFrequency reach and sensitivity. The UTS3015T+ covers 9 kHz to 1.5 GHz; the UTS3032T+ covers 9 kHz to 3.2 GHz. Both models share the same typical noise floor at their top frequencies, plus the same 10,001-point sweep engine, four traces, RBW range, touch interface and built-in tracking generator. The difference is frequency reach: 1.5 GHz versus 3.2 GHz. See \u003cem\u003eChoosing Your Model\u003c\/em\u003e above.\u003c\/p\u003e\n\u003ch3\u003eCan it do EMI pre-compliance?\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit, yes. It adds CISPR-bandwidth RBWs (200 Hz, 9 kHz, 120 kHz, 1 MHz), quasi-peak and EMI-average detectors and editable limit lines for screening with a near-field probe set before a formal compliance run.\u003c\/p\u003e\n\u003ch3\u003eHow is it controlled remotely?\u003c\/h3\u003e\n\u003cp\u003eFull SCPI over USB or LAN (VXI11). It integrates with Python, LabVIEW and MATLAB through standard VISA.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3015T_UTS3032T_Datasheet.pdf\" target=\"_blank\" title=\"UTS3015T\/UTS3032T Datasheet\" rel=\"noopener\"\u003e\u003cimg alt=\"UTS3036T_UTS3084T Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3015T_UTS3032T_Datasheet.pdf\" target=\"_blank\" title=\"UTS3015T \/ UTS3032T Datasheet\" rel=\"noopener\"\u003eUNI-T UTS3015T+ Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T+ Users Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3015T+  Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53780027965624,"sku":"181200100035X","price":1299.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0532\/3735\/0584\/files\/UTS3084T__RS-S_d1013c7d-a9bc-4e80-8ed2-589f8aac1aa8.png?v=1784317769","url":"https:\/\/sperscientific.com\/products\/uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator","provider":"Sper Scientific Instruments","version":"1.0","type":"link"}