{"product_id":"ut8804e-4-8-digit-advanced-series-bench-digital-multimeter","title":"UT8804E 4.8 Digit Advanced-Series Bench Digital Multimeter","description":"\u003ch1\u003eUNI-T UT8804E Advanced-Series Bench Digital Multimeter is a 4⅚-digit auto-ranging True-RMS meter with 0.025% basic DC voltage accuracy, a 59,999-count display and a 4.3in TFT-LCD with digitized analog bar graph.\u003c\/h1\u003e\n\u003cp\u003eData recording, statistical analysis, trend-chart visualization, and Pass\/Fail batch comparison are built in. For R\u0026amp;D bench validation, burn-in monitoring, and small-batch quality control where a basic 4½-digit meter lacks the recording-and-statistics workflow but a 6½-digit unit would be overkill, the UT8804E delivers measurement, logging, and analysis in one instrument. Thermocouple temperature measurement, multiple parameters per measurement function and USB-Device PC connectivity are standard.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4⅚-digit, 59,999-count display\u003c\/strong\u003e — 0.025% basic DC voltage accuracy at the tier price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS AC measurement\u003c\/strong\u003e — accurate readings on non-sinusoidal waveforms (switching supplies, motor drives, PWM, dimmed loads).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-ranging\u003c\/strong\u003e — across voltage, current, resistance, and capacitance functions, reducing operator workflow friction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple temperature measurement\u003c\/strong\u003e — range -40°C to 1000°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData recording with statistics and trend-chart display\u003c\/strong\u003e — Pass\/Fail comparison for batch device testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Device PC connection\u003c\/strong\u003e — included software for historical-data viewing and trend monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UT8804E Details\u003c\/h2\u003e\n\u003ch3\u003e4⅚-Digit Display and 0.025% Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe UT8804E delivers a \u003cstrong\u003e4⅚-digit 59,999-count\u003c\/strong\u003e display with \u003cstrong\u003e0.025% basic DC voltage accuracy\u003c\/strong\u003e. DC voltage resolution is \u003cstrong\u003e0.001 mV\u003c\/strong\u003e and DC current resolution is \u003cstrong\u003e0.01μA\u003c\/strong\u003e — covering the precision needed for component validation, prototype bring-up, and general bench measurement. Resistance resolution is \u003cstrong\u003e0.01Ω\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eMeasurement Function Coverage\u003c\/h3\u003e\n\u003cp\u003eMeasurement coverage includes AC\/DC voltage, AC\/DC current, resistance, capacitance, diode, continuity, frequency, duty cycle, temperature (thermocouple). Capacitance measurement extends to \u003cstrong\u003e60 mF\u003c\/strong\u003e. Frequency counter range is \u003cstrong\u003e60 Hz – 60 MHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTrue-RMS AC Measurement\u003c\/h3\u003e\n\u003cp\u003eTrue-RMS AC measurement delivers correct readings on distorted, non-sinusoidal waveforms — switching-mode power supply outputs, motor-drive currents, dimmed lighting loads, PWM signals — where an average-responding meter would read low. AC voltage and AC current measurements are both True-RMS.\u003c\/p\u003e\n\u003ch3\u003eData Recording and Trend Analysis\u003c\/h3\u003e\n\u003cp\u003eData recording captures historical measurements with real-time access to the current sample count, recording duration, extreme values, and averages. Recorded data renders as both statistical summary and trend chart; the cursor on the trend chart returns the value at a specific time point, useful for isolating anomalies in time-varying signals.\u003c\/p\u003e\n\u003ch3\u003eMultiple Parameters per Measurement Function\u003c\/h3\u003e\n\u003cp\u003eFor each measurement function, the UT8804E exposes multiple parameter selections — for example, capacitance measurement can also display dissipation factor (D) or quality factor (Q) as a secondary parameter. The dual-parameter readout reduces function-key presses on multi-step measurement tasks and keeps both values visible during recording.\u003c\/p\u003e\n\u003ch3\u003ePass\/Fail Comparison for Batch Testing\u003c\/h3\u003e\n\u003cp\u003ePass\/Fail comparison sets a tolerance window around an expected value; readings outside the window trigger an audible alarm and a visual indicator. For batch production-test work — incoming component inspection, finished-board QC, post-burn-in verification — Pass\/Fail flagging removes the operator-attention burden of reading the numeric display on every part.\u003c\/p\u003e\n\u003ch3\u003eMax \/ Min \/ Average Statistics with Timestamps\u003c\/h3\u003e\n\u003cp\u003eMaximum, minimum, and average value statistics track measurement extremes across a batch or time window. Each extreme reading is timestamped, so the trend chart cursor can return both the value and the moment it occurred — useful for isolating intermittent events in long-running tests.\u003c\/p\u003e\n\u003ch3\u003eTemperature Measurement\u003c\/h3\u003e\n\u003cp\u003eThermocouple temperature measurement covers the range \u003cstrong\u003e-40°C to 1000°C\u003c\/strong\u003e with built-in cold-end compensation. Suitable for component-thermal-test, environmental monitoring, and process-temperature verification.\u003c\/p\u003e\n\u003ch3\u003eConnectivity and Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB-Device connection to a host PC enables real-time historical-data viewing, trend-chart display, and configuration backup through the included software. For workbench logging and remote monitoring of long-running tests where a separate data logger would be overkill, USB-Device provides the path.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Bench Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4⅚-digit measurement on prototype boards, switching-supply outputs, and sensor circuits.\u003c\/li\u003e\n\u003cli\u003eData recording during burn-in or temperature-cycle testing with trend-chart visualization.\u003c\/li\u003e\n\u003cli\u003eMaximum\/minimum statistics for capturing intermittent events during long-duration tests.\u003c\/li\u003e\n\u003cli\u003eComponent-thermal monitoring via thermocouple input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmall-Batch Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePass\/Fail batch acceptance testing with audible alarm on out-of-spec readings.\u003c\/li\u003e\n\u003cli\u003eStatistical summary across a production batch (max, min, average, sample count).\u003c\/li\u003e\n\u003cli\u003eMulti-parameter validation within a single measurement function via secondary parameter readout.\u003c\/li\u003e\n\u003cli\u003eUSB-Device connection to a host PC for measurement logging and historical-data review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUniversity and Vocational Teaching Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMid-tier benchtop measurement instruction for second-year electronics and electrical engineering programs.\u003c\/li\u003e\n\u003cli\u003eMeasurement-fundamentals coursework covering recording, statistics, and trend visualization.\u003c\/li\u003e\n\u003cli\u003eCapstone project measurement with True-RMS AC and Pass\/Fail flagging.\u003c\/li\u003e\n\u003cli\u003eCost-effective stocking across multi-bench classroom installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Digits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4⅚ (4.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic DC Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Current Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Reading Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 rdgs\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance Range (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz – 60 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMath \/ Statistics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax\/Min\/Average, Pass\/Fail, Relative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3in TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOptions and Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT8804E benchtop digital multimeter\u003c\/li\u003e\n\u003cli\u003eStandard test lead set\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eUSB-Device cable for PC connection\u003c\/li\u003e\n\u003cli\u003ePC software (included; downloadable from uni-trend.com)\u003c\/li\u003e\n\u003cli\u003eUser manual and factory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType-K thermocouple probe\u003c\/strong\u003e — for temperature measurement across the supported range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8802E\u003c\/strong\u003e — Value-tier 4½-digit manual-range bench DMM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8803E\u003c\/strong\u003e — Classic-tier 3⅚-digit auto-ranging bench DMM with inductance and D\/Q.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8804E\u003c\/strong\u003e — Advanced-tier 4⅚-digit bench DMM with data recording and Pass\/Fail. \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8805E\u003c\/strong\u003e — Performance-tier 5½-digit SCPI bench DMM with four-wire resistance and math.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806E\u003c\/strong\u003e — Performance-tier 6½-digit SCPI bench DMM (LAN\/RS-232\/USB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806EG\u003c\/strong\u003e — Performance-tier 6½-digit bench DMM with IEEE-488.2 GPIB (substitutes for RS-232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eHow does the UT8804E compare to other models in the UT8800E series?\u003c\/h3\u003e\n\u003cp\u003eThe UT8804E is the mid-tier Advanced model: 4⅚-digit precision with True-RMS, auto-ranging, a 4.3-inch TFT-LCD, data recording with trend-chart display, and Pass\/Fail batch comparison. It sits between the Classic UT8803E and the Performance-cohort UT8805E. If your work needs SCPI automation, fast reading rates, or four-wire resistance, step up to UT8805E or UT8806E.\u003c\/p\u003e\n\u003ch3\u003eCan I connect the UT8804E to a PC for data logging?\u003c\/h3\u003e\n\u003cp\u003eYes. The USB-Device port connects the UT8804E to a host PC running the included software, which provides real-time historical-data viewing, trend-chart display, and configuration backup. The software is included free of charge; firmware updates over the product's lifetime are free.\u003c\/p\u003e\n\u003ch3\u003eIs the UT8804E factory-calibrated, and how often does it need recalibration?\u003c\/h3\u003e\n\u003cp\u003eYes — every UT8804E ships with a factory calibration certificate. The recommended recalibration interval is once per year for metrology-traceable measurement applications. For routine workbench use where the meter is being used for relative comparisons or go\/no-go checks against known references, longer intervals are acceptable. Recalibration is performed through Uni-Trend or an accredited third-party calibration laboratory.\u003c\/p\u003e\n\u003ch3\u003eWhat probes and accessories ship with the UT8804E?\u003c\/h3\u003e\n\u003cp\u003eThe UT8804E ships with the standard probe and lead set appropriate to its measurement range, a power cord, the USB-Device cable for PC connection, the included software disc or download link, a user manual, and the factory calibration certificate. Verify the included contents against the packing list on delivery.\u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53766961627320,"sku":"180908080071X","price":269.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0532\/3735\/0584\/files\/UT8804E_1_sq.jpg?v=1784065128","url":"https:\/\/sperscientific.com\/products\/ut8804e-4-8-digit-advanced-series-bench-digital-multimeter","provider":"Sper Scientific Instruments","version":"1.0","type":"link"}